Heat-exchange equipment

Oil coolers

Oil coolers OKP 2,3-170

Oil coolers OKP 2,3-170

FUNCTION AND TECHNICAL DATA: The cooler is intended to cool oil, hydraulic systems liquids, fresh and sea water in systems of marine power stations; cool auxiliaries and other systems of ships and vessels.;
Medium to be cooled : turbine oil;
Cooling medium: sea water;
Hydraulic resistance of the medium to be cooled, MPa (kg-f/cm²): 0,18(1,8);
Hydraulic resistance of the cooling medium, MPa (kg-f/cm²): 0,02(0,2);
The material of the body: stainless steel;
Oil coolers OKN 1,0-170

Oil coolers OKN 1,0-170

FUNCTION AND TECHNICAL DATA: The cooler is intended to cool oil, hydraulic systems liquids, fresh and sea water in systems of marine power stations; cool auxiliaries and other systems of ships and vessels.;
Medium to be cooled: turbine oil;
Cooling medium: sea water;
Hydraulic resistance of the medium to be cooled, MPa (kg-f/cm²): 0,04(0,4);
Hydraulic resistance of the cooling medium, MPa (kg-f/cm²): 0,012(0,12);
The material of the body: stainless steel;
Oil coolers OKN 1,0-170 ND

Oil coolers OKN 1,0-170 ND

FUNCTION AND TECHNICAL DATA: The cooler is intended to cool oil, hydraulic systems liquids, fresh and sea water in systems of marine power stations; cool auxiliaries and other systems of ships and vessels.;
Medium to be cooled: turbine oil;
Cooling medium: sea water;
Hydraulic resistance of the medium to be cooled, MPa (kg-f/cm²): 0,04(0,4);
Hydraulic resistance of the cooling medium, MPa (kg-f/cm²): 0,012(0,12);
The material of the body: stainless steel;
Oil coolers OKP 17-420

Oil coolers OKP 17-420

FUNCTION AND TECHNICAL DATA: The cooler is intended to cool oil, hydraulic systems liquids, fresh and sea water in systems of marine power stations; cool auxiliaries and other systems of ships and vessels.;
Medium to be cooled: turbine oil;
Cooling medium: sea water;
Hydraulic resistance of the medium to be cooled, MPa (kg-f/cm²): 0,1(1,0);
Hydraulic resistance of the cooling medium, MPa (kg-f/cm²): 0,02(0,2);
The material of the body: stainless steel;
Oil coolers OKP 29-420

Oil coolers OKP 29-420

FUNCTION AND TECHNICAL DATA: The cooler is intended to cool oil, hydraulic systems liquids, fresh and sea water in systems of marine power stations; cool auxiliaries and other systems of ships and vessels.;
Medium to be cooled: gas-turbine oil;
Cooling medium: sea water;
Hydraulic resistance of the medium to be cooled, MPa (kg-f/cm²): 0,04(0,4);
Hydraulic resistance of the cooling medium, MPa (kg-f/cm²): 0,027(0,27);
The material of the body: stainless steel;
Oil coolers OKP 58-600

Oil coolers OKP 58-600

FUNCTION AND TECHNICAL DATA: The cooler is intended to cool oil, hydraulic systems liquids, fresh and sea water in systems of marine power stations; cool auxiliaries and other systems of ships and vessels.;
Medium to be cooled: turbine oil (for mode 1), gas-turbine oil (for mode 2);
Cooling medium: sea water;
Hydraulic resistance of the medium to be cooled, MPa (kg-f/cm²): 0,12(1,2);
Hydraulic resistance of the cooling medium, MPa (kg-f/cm²): 0,025(0,25) - for mode 1, 0,05(0,5) - for mode 2;
The material of the body: stainless steel;
Oil coolers OKP 90-700

Oil coolers OKP 90-700

FUNCTION AND TECHNICAL DATA: The cooler is intended to cool oil, hydraulic systems liquids, fresh and sea water in systems of marine power stations; cool auxiliaries and other systems of ships and vessels.;
Medium to be cooled: turbine oil;
Cooling medium: sea water;
Hydraulic resistance of the medium to be cooled, MPa (kg-f/cm²): 0,05(0,5);
Hydraulic resistance of the cooling medium, MPa (kg-f/cm²): 0,042(0,42) - for mode 1, 0,05(0,5) - for mode 2;
The material of the body: stainless steel;
Oil coolers OKP 190-920

Oil coolers OKP 190-920

FUNCTION AND TECHNICAL DATA: The cooler is intended to cool oil, hydraulic systems liquids, fresh and sea water in systems of marine power stations; cool auxiliaries and other systems of ships and vessels.;
Medium to be cooled: Mixture: 65% of turbine oil GOST 10289-78 and 35% of oil МС-20 GOST21743-76 (mode1,2); turbine oil Тп-46 GOST 9972-74 (mode3,4), fresh water (mode 5);
Max.working pressure of the medium to be cooled, MPa (kg-f/cm²): 1,0(10,0);
Cooling medium: sea water;
Max.working pressure of the medium to the cooling medium, MPa (kg-f/cm²): 0,6(6,0);
Estimated heat-exchange surface, m³: 190;
Oil cooler, MKhD

Oil cooler, MKhD

FUNCTION AND TECHNICAL DATA: Oil coolers are intended to be installed in cooling systems of power installations on small fast ships, vessels and boats;
Oil cooler, MO-25V

Oil cooler, MO-25V

NAME AND TECHNICAL DATA: Oil cooler MO-25V is used on the atomic power station and intended to cool oil, delivered to bearings of fluid flywheel and main feed pump.;
The oil cooler is tube-and-shell exchanger, vertical, four-pass as to process water and single-pass as to oil with a multiple flow of matrix: Matrix material: steel 08Х18Н10Т (or12Х18Н10Т);
Body material: steel Ст3сп5 (or steel 20): Location of oil inlet/outlet branch pipes: At the lower and upper part of the oil cooler, with the angle of 90 °С;
General dimensions (HxW), mm: 2139x839;
Matrix material: steel 08Х18Н10Т (or12Х18Н10Т): Body material: steel 20 (or 09Г2С or 22K);
Location of oil inlet/outlet branch pipes: At the upper part of the oil cooler, with the angle of 90 °С: ;
Oil cooler, MO-63-1-M

Oil cooler, MO-63-1-M

NAME AND TECHNICAL DATA: Oil cooler MO-63-1-M is used on atomic power station and intended to cool turbine oil, delivered to the main recirculating pump.;
The oil cooler is tube-and-shell exchanger, horizontal, two-pass as to process water and single-pass as to oil with a multiple flow of oil: Cooling medium in tube side: process water;
Medium to be cooled in the tube space: turbine oil Тп-22: ;

Water coolers

Water coolers OKN 7,5-310

Water coolers OKN 7,5-310

FUNCTION AND TECHNICAL DATA: The cooler is intended to cool oil, hydraulic systems liquids, fresh and sea water in systems of marine power stations; cool auxiliaries and other systems of ships and vessels.;
Medium to be cooled: fresh water;
Cooling medium: sea water;
Hydraulic resistance of the medium to be cooled, MPa (kg-f/cm²): 0,025(0,25);
Hydraulic resistance of the cooling medium, MPa (kg-f/cm²): 0,02(0,2);
The material of the body: stainless steel;
Water coolers OKN 9,7-420

Water coolers OKN 9,7-420

FUNCTION AND TECHNICAL DATA: The cooler is intended to cool oil, hydraulic systems liquids, fresh and sea water in systems of marine power stations; cool auxiliaries and other systems of ships and vessels.;
Medium to be cooled: fresh water;
Cooling medium: sea water;
Hydraulic resistance of the medium to be cooled, MPa (kg-f/cm²): 0,07(0,7);
Hydraulic resistance of the cooling medium, MPa (kg-f/cm²): 0,04(0,4);
The material of the body: stainless steel;
Water coolers OKN 28,6-600

Water coolers OKN 28,6-600

FUNCTION AND TECHNICAL DATA: The cooler is intended to cool oil, hydraulic systems liquids, fresh and sea water in systems of marine power stations; cool auxiliaries and other systems of ships and vessels.;
Medium to be cooled: fresh water;
Cooling medium: sea water;
Hydraulic resistance of the medium to be cooled, MPa (kg-f/cm²): 0,06(0,6);
Hydraulic resistance of the cooling medium, MPa (kg-f/cm²): 0,02(0,2);
The material of the body: stainless steel;
Water coolers OKP 3,4-170

Water coolers OKP 3,4-170

FUNCTION AND TECHNICAL DATA: The cooler is intended to cool oil, hydraulic systems liquids, fresh and sea water in systems of marine power stations; cool auxiliaries and other systems of ships and vessels.;
Medium to be cooled: fresh water;
Cooling medium: sea water;
Hydraulic resistance of the medium to be cooled, MPa (kg-f/cm²): 0,01(0,1)-mode 1; 0,05(0,5) - mode 2;
Hydraulic resistance of the cooling medium, MPa (kg-f/cm²): 0,1(1,0) - mode 1, 0,12(1,2) - mode 2;
The material of the body: stainless steel;
Water coolers OPV

Water coolers OPV

FUNCTION AND TECHNICAL DATA: The cooler is intended to cool oil, hydraulic systems liquids, fresh and distilled water, as well as sea water in systems of marine power stations; cool auxiliaries and other systems of ships and vessels.;
Working (design) pressure of the cooling water, MPa (kg-f/cm²), max: 6,4 (64) for OPV 14-3, OPV-17, OPV-47, OPV-135 8,5 (85) for OPV-155;
Medium to be cooled: distilled or fresh water;
Water cooler, VKhD type

Water cooler, VKhD type

FUNCTION AND TECHNICAL DATA: Water coolers of VKhD type with planar tubes are intended to be installed in cooling systems of power installations on small fast ships, vessels and boats.;
Medium: water;
Type: Shell-and-tube with flat tubes, single pass as for water to be cooled;
Cooling medium: sea water;

Oil and water coolers

Oil and water coolers OKN 0,2-74

Oil and water coolers OKN 0,2-74

FUNCTION AND TECHNICAL DATA: The cooler is intended to cool oil, hydraulic systems liquids, fresh and sea water in systems of marine power stations; cool auxiliaries and other systems of ships and vessels.;
Medium to be cooled: spindle oil (mode 1), fresh water (mode 2);
Cooling medium: sea water;
Hydraulic resistance of the medium to be cooled, MPa (kg-f/cm²): 0,05(0,5) - mode 1,2; 0,07(0,7) - mode 3;
Hydraulic resistance of the cooling medium, MPa (kg-f/cm²): 0,01(0,1);
The material of the body: Cu-Ni alloy;
Oil and water coolers OKN 2,5-170

Oil and water coolers OKN 2,5-170

FUNCTION AND TECHNICAL DATA: The cooler is intended to cool oil, hydraulic systems liquids, fresh and sea water in systems of marine power stations; cool auxiliaries and other systems of ships and vessels.;
Medium to be cooled: spindle oil (mode 1,2); fresh water (mode 3);
Cooling medium: sea water;
Hydraulic resistance of the medium to be cooled, MPa (kg-f/cm²): 0,05(0,5) - mode 1,2; 0,02(0,2) - mode 3;
Hydraulic resistance of the cooling medium, MPa (kg-f/cm²): 0,03(0,3) - mode 1,2; 0,02 (0,2) - mode 3;
The material of the body: Cu-Ni alloy;
Oil and water coolers OKN 15,8-420

Oil and water coolers OKN 15,8-420

FUNCTION AND TECHNICAL DATA: The cooler is intended to cool oil, hydraulic systems liquids, fresh and sea water in systems of marine power stations; cool auxiliaries and other systems of ships and vessels.;
Medium to be cooled: turbine oil (mode 1,2); fresh water (mode 3);
Cooling medium: sea water;
Hydraulic resistance of the medium to be cooled, MPa (kg-f/cm²): 0,026(0,26) - mode 1,2; 0,025(0,25) - mode 3;
Hydraulic resistance of the cooling medium, MPa (kg-f/cm²): 0,0065(0,065) - mode 1; 0,008(0,08) - mode 2; 0,04(0,4) - mode 3;
The material of the body: stainless steel;
Oil and water coolers OKN 26,9-420

Oil and water coolers OKN 26,9-420

FUNCTION AND TECHNICAL DATA: The cooler is intended to cool oil, hydraulic systems liquids, fresh and sea water in systems of marine power stations; cool auxiliaries and other systems of ships and vessels.;
Medium to be cooled: turbine oil (mode 1,2); fresh water (mode 3);
Cooling medium: sea water;
Hydraulic resistance of the medium to be cooled, MPa (kg-f/cm²): 0,085(0,85) - mode 1,2; 0,02(0,2) - mode 3;
Hydraulic resistance of the cooling medium, MPa (kg-f/cm²): 0,025(0,25) - mode 1; 0,014(0,14) - mode 2; 0,04(0,4) - mode 3;
The material of the body: stainless steel;
Oil and water coolers OKN 108-700

Oil and water coolers OKN 108-700

FUNCTION AND TECHNICAL DATA: The cooler is intended to cool oil, hydraulic systems liquids, fresh and sea water in systems of marine power stations; cool auxiliaries and other systems of ships and vessels.;
Medium to be cooled: turbine oil (mode 1,2); fresh water (mode 3,4);
Cooling medium: sea water;
Hydraulic resistance of the medium to be cooled, MPa (kg-f/cm²): 0,06(0,6) - mode 1; 0,1(1,0) - mode 2,3; 0,05(0,5) - mode 4;
Hydraulic resistance of the cooling medium, MPa (kg-f/cm²): 0,01(0,1) режим 1,2; 0,05(0,5) - режим 3,4;
The material of the body: stainless steel;
Oil and water coolers OKN 220-1050

Oil and water coolers OKN 220-1050

FUNCTION AND TECHNICAL DATA: The cooler is intended to cool oil, hydraulic systems liquids, fresh and sea water in systems of marine power stations; cool auxiliaries and other systems of ships and vessels.;
Medium to be cooled: turbine oil (mode 1,2); fresh water (mode 3);
Cooling medium: sea water;
Hydraulic resistance of the medium to be cooled, MPa (kg-f/cm²): 0,13(1,3) - mode 1,2; 0,07(0,7) - mode 3;
Hydraulic resistance of the cooling medium, MPa (kg-f/cm²): 0,01(0,1) - mode 1; 0,02(0,2) - mode 2; 0,017 (0,17) - mode 3;
The material of the body: stainless steel;

Other coolers

Condensate cooler KhV 2.5

Condensate cooler KhV 2.5

FUNCTION AND TECHNICAL DATA: Coolers of such a type are intended to cool oil, hydraulic systems liquids, fresh and sea water in systems of marine power stations; cool auxiliaries and other systems of ships and vessels.;
Consumption of condensate, entering the cooler, kg/h: 23 000;
Cooling surface, m²: 2,5;
Size of heat-exchange pipes (outer diameter, wall thickness), mm: 10х1,0;
Mass (dry/active), kg: 173/179,5;
Cooler PGV-80

Cooler PGV-80

FUNCTION AND TECHNICAL DATA: The cooler is intended to cool PGV liquids in special systems of ships.;
Medium to be cooled: PGV-80 liquid under GOST 25821-83;

Water, oil and fuel heaters

High-speed hot-water heaters, PS type

High-speed hot-water heaters, PS type

FUNCTION AND TECHNICAL DATA: Heaters are intended to heat fresh washing, sea and fresh drinking water. Heaters are part of the equipment for ablutions (shower cubicles, washrooms, cabooses, dishwashing rooms).;
Steam pressure under the max.productivity, MPa (kg-f/cm²): 0,5(5,0);
Type: shell-and-tube;
The heating element: is of a helical spiral type;
The working position: vertical;
The heating medium: dry prime steam;
Capacitive water heaters, PE type

Capacitive water heaters, PE type

FUNCTION AND TECHNICAL DATA: Heaters are intended to heat washing and fresh drinking water. Heaters are part of the equipment for ablutions.;
Type: shell-and-tube with heat-exchange tubes of U-shape.;
Design: horizontal and vertical, depending on the installation.;
High-speed hot-water heaters, PV type

High-speed hot-water heaters, PV type

FUNCTION AND TECHNICAL DATA: Heaters are intended to heat drinking and fresh washing water for ablutions in ships, vessels, watercrafts, etc.;
Medium to be heated: drinking water and fresh washing water;
Max pressure of prime steam, MPa (kg-f/cm²): 0,5(5,0);
High-speed hot-water heaters, PJe type

High-speed hot-water heaters, PJe type

FUNCTION AND TECHNICAL DATA: The heater is intended to heat water for ablutions.;
Medium: water;
Voltage, V: 220/380;
High-speed hot-water heaters, PPJe type

High-speed hot-water heaters, PPJe type

FUNCTION AND TECHNICAL DATA: The heater is intended to heat water for ablutions.;
Medium: water;
Voltage, V: 220/380;
Marine steam oil heaters, PM type

Marine steam oil heaters, PM type

FUNCTION AND TECHNICAL DATA: Heaters are intended to heat oil in oil separation systems, as well as for other purposes, in electric power installations of ships and vessels.;
The principle of operation:: the medium to be heated enters the pipe cavity, washed by the steam, then it is heated to the required temperature and delivered to the Customer.;
Type: shell-and-tube type with heat-exchange pipes of U-shape.;
The medium to be heated: engine oil M 16D, M-16E30, turbine oil T57, spindle oil AU.;
The heating medium: prime steam;
Exhausted steam condenser, KhV type

Exhausted steam condenser, KhV type

FUNCTION AND TECHNICAL DATA: The condenser is installed on ships of all types, and is intended to condense the steam and cool the condensate. ;
Material of the body: stainless steel;
Sizes of heat exchange pipes (external diameter, wall thickness), mm: 16x1,5, 16x1,0;
Material of covers: Cu or bronze;
Material of tube plates: brass;
Pressure of the cooling water, MPa (kg-f/cm²): 0,35 (3,5) - for KhV 4,3; 0,3(3,0) - for KhV 9,1;
Cooling surface, m²: 4,5 - for KhV 4,3; 23,1 - for KhV 9,1;
Exhausted steam condenser, KhV 200

Exhausted steam condenser, KhV 200

FUNCTION AND TECHNICAL DATA: The condenser is installed on ships of unristricted navigation and is intended to condense the steam and cool the condensate. The condenser is of surface nonseparable type, horizontak with planar tubes, two-way as for the cooling medium.;
Cooling medium: sea water;
Cooling surface, m²: 176,2;
Weight, kg: 5000/6100;
Pressure in the condenser:: atmospheric, 0,4 (4);
Cooling medium permissible pressure loss, MPa(kg-f/cm²): 0,035 (0,35);